HQ 150W

HQ 150W shall charge a Lead-acid batteries with CC/CV/Floating profile.
Dip switch on left for GEL battery and right for AGM battery.

Highlighted Features:

  • IP54 Water & Dust Proof
  • Support customization onboard mount
  • Medical Approval
  • High efficiency and low temperature
  • User selectable dip-switch for charging two battery type
  • Key components with global leading brand
  • SKU: 17 Category:

    HQ150 2D尺寸图.png

    Output Voltage (support customized algorithm)
    Fast Charge (AGM) DC 29.6V (+ / – 0.2V) Fast Charge (GEL) DC 28.8V (+ / – 0.2V)
    Float Charge (AGM) DC 27.3V (+ / – 0.2V) Float Charge (GEL) DC 25.7V (+ / – 0.2V)
    Charging Current
    Fast Charge DC 5A + / – 10%
    Float Charge < DC 800 mA
    Maintenance Stage [email protected]
    Input Voltage 100 – 240 Vac + / -10% Input Frequency 50 – 60 Hz
    Over Voltage Protection DC 31V Max. Over Current Protection DC 6A Max.
    Leakage Current 0.75mA Max. Input Power 180W
    Input Standby Power 0.5W Effciency > 85% @ Full Load
    Battery Charging Capacity 15 – 50 Amp Hours Output Cord 2m long, SJT type (Hard Usage) with XLR
    3-pin Male Connector
    Dielectric Withstand Voltage AC 3.0KV for 1 min. @ 10mA leakage Insulation Resistance 50Mohm Min. at 500Vdc between Primary and Secondary
    Operation Temperature 0°C to +40°C Storage Temperature -20°C to +60°C
    Safety Standards IEC / EN 60335-2-29, BS EN 60335-2-29, UL 1012, CSA C22.2#107.2, EN 55014-1, EN 55014-2, IEC / EN 61000-3-2, IEC / EN 61000-3-3, AS / NZS CISPR 14.1-2013, ISO 7176-21, ISO 7176-25, ISO7176-14, ISO 7176-15, DOE 10 CFR 430.32 (z), CEC-140-2019-002

    2 LEDs for Status Indication
    1. Power LED (Clear Lens – Red Color)
    Description LED
    Power On On
    No AC Power Off
    2. Charging / Faults – LED (Clear Lens – Red / Green Color)
    Charging – Description Red LED Green LED
    No Battery / Full Charge (20 Hrs) Off Off
    Bulk /Absorption Charge On Off
    Float Charge Off Continuous Blinking
    Maintenance Charge Off On Steady

    INDICATION CHARGE / FAULT – Red LED FAULT
    LED is off No batteries – Voltage < 9V
    LED – continuous rapid flashing 12 hr. charge timed out
    LED – 1 flashes every 3 sec Battery voltage < 14V
    LED – 2 flashes every 3 sec Batteries are connected in reverse polarity
    LED – 3 flashes every 3 sec Over voltage from batteries
    LED – 4 flashes every 3 sec Over current from charger